STC / SCIF Sound Proof Doors

ICD 705 DOOR Assemblies Complete with All FF-L 2890 & 2740 Hardware. Full Certified Installation.

Important Considerations When Selecting A Manufacturer and Installer For You STC Door

Manufacturer Lead-Times:

  • Make Sure That Lead-time Includes Engineering, Manufacturing, Delivery and Installation

Doors and Frames Should Be Tested As Operable Assemblies:

  • Some Manufacturer’s Use Fillers Between The Door Edge and The Frame During Testing. This Test Is Not Representative Of The Actual Conditions That Your Door Will Be Subjected During Operation

Wall Construction Is Never 100% Plumb, Level and Square. Your Assembly Should Be Constructed To Handle Real Site Conditions Within An Acceptable Tolerance:

  • Your Manufacturer Should Have Allowable Installation Tolerances

Your Seal System Should Be Adjustable To Accommodate Real Field Conditions

  • Some manufacturers use self adhesive, non-adjustable seals

There Is No Such Thing As An ICD-705 Certified Door and Frame Assembly:

  • ICD-705 Only Includes Requirements For Your SCIF Perimeter Doors
  • There Is No Certifying Body For ICD-705 Doors
  • It Is Up To Your SCIF Accreditor Who Will Approve The SCIF Space Including Your SCIF Doors.

Stock Program Overview

Houston-Starr maintains secured custody from our warehouse to the jobsite providing
 the fastest lead-times in the industry.

Mid-Atlantic service area lead-times are dependent on specific job requirements and size of project.

Complete Opening Installation by Houston-Starr’s factory certified installation 
team provides your client with a high quality installation to ensuring your sound
 door assembly performs and your client can remain on mission.

We Stock The FF-L-2890B Approved LKM10K w/ FF-L-2740B Approved Kaba Mas X-10 Series Lock

Hollow Metal Stock STC-46/Field STC-41 Assembly Package

Single Doors Both 3070 and 3080:

  • Magnetic Seals
  • Level Swing Hinges
  • Automatic Door Bottom
  • Flat ½” Tall Saddle Threshold

Double Doors 6070 and 6080:

  • Compression Seals With Overlapping Astragal

Flush Hollow Metal Door

Split Jamb Frame Construction With Existing Wall Anchors (Masonry Or Wood)

Accommodates Wall Conditions From 4-7/8 to 11” Throat

Houston-Starr Supplied and Installed Hardware

Houston-Starr Certified Installation Of The Entire Opening Required

Hardware Available:

  • Dorma Kaba DKX Series
  • Lockmaster LKM10K Series
  • Sargent and Greenleaf 2890B Series
  • Kaba Mas CDX-10
  • Mortise Lockset with Electrified Options
  • Cylindrical Lockset With Electrified Options
  • Rim Exit Device With Electrified Options
  • Electric Power Transfer (EPT)
  • Surface Mounted Closers
  • Other Hardware Application May be Available Upon Special Request

Hollow Metal Stock STC-50/ Field STC-45 Assembly Package

Single Doors Both 3070 and 3080:

  • Magnetic Seals
  • Cam-Lift Hinges
  • Fixed Door Bottom
  • Flat ½” Tall Saddle Threshold

Double Doors 6070 and 6080:

  • Compression Seals With Overlapping Surface Astragal
  • Single Active Leaf With Inactive Leaf Secured By Heavy Duty Lockable Surface Bolt

Split Jamb Frame Construction With Existing Wall Anchors (Masonry Or Wood)

Accommodates Wall Conditions From 4-7/8 to 11” Throat

Houston-Starr Supplied and Installed Hardware

Houston-Starr Certified Installation Of The Entire Opening Required

Hardware Available:

  • Dorma Kaba DKX Series
  • Lockmaster LKM10K Series
  • Sargent and Greenleaf 2890B Series
  • Kaba Mas CDX-10
  • Mortise Lockset with Electrified Options
  • Cylindrical Lockset With Electrified Options
  • Rim Exit Device With Electrified Options
  • Electric Power Transfer (EPT)
  • Surface Mounted Closers
  • Other Hardware Application Maybe Available Upon Special Request

Stock Hollow Metal STC-52/ Field STC-47 Assembly Package

Single Doors Both 3070 and 3080:

  • Compression Seals
  • Cam-Lift Hinges
  • Fixed Door Bottom
  • Flat ½” Tall Saddle Threshold

Double Doors 6070 and 6080:

  • Compression Seals With Overlapping Astragal

Split Jamb Frame Construction With Existing Wall Anchors (Masonry Or Wood)

Accommodates Wall Conditions From 4-7/8” to 11” Throat

Houston-Starr Supplied and Installed Hardware

Houston-Starr Certified Installation Of The Entire Opening Required

Hardware Available:

  • Dorma Kaba DKX Series
  • Lockmaster LKM10K Series
  • Sargent and Greenleaf 2890B Series
  • Kaba Mas CDX-10
  • Mortise Lockset with Electrified Options
  • Cylindrical Lockset With Electrified Options
  • Rim Exit Device With Electrified Options
  • Electric Power Transfer (EPT)
  • Surface Mounted Closers
  • Other Hardware Application Maybe Available Upon Special Request

Quick Ship Hollow Metal STC-53 Assembly Package

Single Doors Sized Both 3270 and 3280:

  • Dual Magnetic Seals
  • Cam-Lift Hinges
  • Fixed Door Bottom
  • Flat ½” Tall Saddle Threshold

Split Jamb Frame Construction With Existing Wall Anchors (Masonry Or Wood)

Accommodates Wall Conditions From 7-1/4” to 11” Throat

Houston-Starr Certified Installation Of The Entire Opening Required

Houston-Starr Supplied and Installed Hardware:

  • Dorma Kaba DKX Series
    • Outswing Doors Only
  • Lockmaster LKM10K Series
  • Sargent and Greenleaf 2890B Series
    • Outswing Doors Only
  • Kaba Mas CDX-10
    • Outswing Doors Only
  • Mortise Lockset with Electrified Options
  • Cylindrical Lockset With Electrified Options
  • Rim Exit Device With Electrified Options
  • Electric Power Transfer (EPT)
  • Surface Mounted Closers
  • Other Hardware Application May be Available Upon Special Request

Custom SCIF STC, STC/RF, Bullet and Blast Specialty Doors

Custom Sizes Available

Hollow Metal STC Lab Rating Up To STC-55

Wood Veneered Doors STC Lab Rating Up To STC-55

TEMPEST Doors Up To STC-50 and Up To RF-60 dB:

  • IEEE 299
  • NSA 73-2A
  • NSA 65-6
  • MIL STD-285

Additional Options Available For Doors:

  • Blast
    • ATFP Anti Terrorism Force Protection
    • Unified Facility Criteria UFC 4-010-01
    • ASTM F2927-12
  • Bullet Resistance (BR)
    • UL 752
    • NIJ 0108.01
    • MIL SAMIT
  • Forced Entry (FE)
    • Department of State SD Std-01.01 Rev. G
  • GSA Class 5- Vault STC Rated Doors
    • Federal Specification AA-D-600D

Contact Houston-Starr For More Information

Download our Brochure

Recommendations

Stock Doors, Hardware Options, Anchor Options, Drywall Partition Construction, Flooring and Painting

Stock STC/SCIF Door Program

  • Single Doors sized as both 3070 and 3080 lab rated STC 50 and 52 Doors
  • Double Doors sized as both 6070 and 6080 lab rated STC 50 Doors
  • Houston-Starr maintains custody from our warehouse to the jobsite providing the fastest lead-times in the industry.
  • Mid-Atlantic service area lead-times are dependent on specific job requirements and size of project.
  • Wall Conditions The partition can be prebuilt using our split jamb frame. We are able to accommodate wall throat sizes ranging from 5” to 12”.
  • Complete Opening Installation by Houston-Starr’s factory certified installation team allows your client to have a high quality install to ensuring your sound door assembly performs and your client can focus on their mission.

STC SCIF Door Diagram
Click for larger pdf image of illustrations

Hardware Options Available

  • Lockmaster LKMs
  • Sargent and Greenleaf 2890B
  • Mortise Lockset
  • Cylindrical Locksets
  • Rim Exit Devices
  • CDX-10
  • Closers both Regular and Parallel Arm
  • Other Hardware Applications maybe available upon special request.

STC SCIF Door Diagram
Click for larger pdf image of illustrations

Anchor Options

  • Heavy Gauge Partition Wood Stud
  • Metal Stud (Built-in)
  • Concrete / Masonry

STC SCIF Door Diagram
Click for larger pdf image of illustrations

Drywall Partition Construction
Recommendations:

  • While constructing your partition, please consider that your will door will weigh approximately 300 lbs
  • Please note heavy gauge stud must run from the floor to the deck
  • Please install wood blocking inside the steel stud to allow for the wood lag screws to anchor correctly to the partition.
  • Rough opening requirements:
    • Rough Opening Width = Nominal Width of Hollow Metal Door + 3”
    • Rough Opening Height = Nominal Height of Hollow Metal Door + 1-1/2”

Flooring

  • Please make sure your floor is level to allow for the bottom door seal to operate correctly.
  • This door cannot be installed on a raised floor, a partition must be built underneath the opening to support the weight of your door and frame assembly.

Painting

  • Please make sure that your paint is fully cured before coming in contact with the sound seals. Typically latex paints take at least 30 days to fully cure. Please check with your paint manufacturer for your specific curing time.
  • Please make sure not to paint any of the seal or hardware on the STC door. Painting the seals will damage the gasketing and could impact your acoustical performance.

STC SCIF Door Diagram
Click for larger pdf image of illustrations

STC SCIF Door Diagram
Click for larger pdf image of illustrations


Talk directly to one of our STC/SCIF Door Experts. Call (571) 491-7522

Download Brochure

MENU